Skip to main content

IRIV EdgeAI Safety Box Kit

IRIV EdgeAI Safety Box Kit

Product code: KIT-IRIV-EAI-PPE · Product page · Quick Start Guide

A ready-to-deploy workplace-safety box. It watches your existing IP cameras for missing PPE and people entering danger zones, raises alarms on two outputs, and keeps an evidence log and PDF safety reports. All AI runs on the device: video does not leave the site, and the system keeps working without internet.

The controller inside is an IRIV EdgeAI CM5 with a 26 TOPS (Hailo-8) AI HAT+ on its PCIe port.

Key Facts​

ItemValue
CamerasUp to 6 RTSP IP camera sub-streams, 640×360 at 15–25 FPS, H.264/H.265
Camera typeIP cameras with RTSP streaming (the software is documented for RTSP only, not CSI cameras)
AI acceleratorRaspberry Pi AI HAT+, Hailo-8, 26 TOPS
EnclosureIP67 ABS industrial enclosure, 250 × 350 × 160 mm
PowerMains via a fused, switched IEC inlet → 24V 36W industrial switching PSU (80–305 VAC or 100–430 VDC input) → controller VIN
Alarm outputsController DO0 = PPE alarm, DO1 = Zones alarm (dry contact, max 50V 500mA)
Operating temperature−20 to 60 °C (assembled box)
LicenceOne-time purchase — no licence or subscription fee
Warranty12 months

Software​

The web interface has five tabs:

TabWhat it does
Live ViewCamera grid with detections drawn live; draw danger zones here. Layouts Auto, Grid, Focus, Single. Smart Live pauses an idle tile after about 30 s and resumes on motion or a detection
AnalyticsCharts and summaries over time
EventsEvidence record (snapshot and short clip) with filters and export
ReportsPDF safety report for a chosen period; a monthly "Workplace Safety Audit" report can be emailed
SettingsCameras, models, alerts, users, system

First sign-in: the front OLED shows the box's IP address — open it in a browser on the same network.

Wiring the Alarm Outputs​

In Settings, each output has an on/off Status and a Timing of Hold or Pulse (with a pulse duration in seconds).

DO0 / DO1 are dry contacts

The outputs are solid-state-relay switches. They do not supply voltage — put the siren or stack light and its own power supply in series across the output's two contacts, max 50V (DC or AC) and 500mA. Fit a flyback diode across inductive loads such as relay coils.

Terminal positions and the rest of the controller I/O: EdgeAI CM5 I/O Reference.

Good to Know​

  • No accuracy figure is published — results depend on lighting, camera angle and site conditions.
  • Do not call the kit "IRIV EdgeAI CM5"; it is a complete solution built on that controller.
  • Controller-level troubleshooting (4A fuse, Boot/Run switch): EdgeAI CM5 Troubleshooting.

Further Reading​


Source(s):

  • IRIV EdgeAI Safety Box Kit product page (my.cytron.io), read Oct 2026
  • IRIV EdgeAI Safety Box Quick Start Guide (Cytron, Aug 2026)
  • Cytron design team answers (Oct 2026); IRIV EdgeAI CM5 Datasheet Rev 1.0